Veritas Access Appliance Initial Configuration and Administration Guide

Last Published:
Product(s): Appliances (7.3.2)
Platform: 3340
  1. Getting to know the Access Appliance
    1.  
      About the Veritas Access Appliance
    2. About the Access Appliance administration interfaces
      1.  
        Using the Access Appliance shell menu
    3.  
      About licensing the Access Appliance
    4. Where to find the documentation
      1.  
        Changes in the Access Appliance document revision
  2. Preparing to configure the appliance
    1.  
      Initial configuration requirements
    2.  
      About obtaining IP addresses for Veritas Access
    3.  
      Network and firewall requirements
  3. Configuring the appliance for the first time
    1. How to configure the Access Appliance for the first time
      1.  
        Configuring the Access cluster on the appliance
  4. Getting started with the Veritas Access GUI
    1.  
      Where to find the Veritas Access GUI
    2. About the Veritas Access 3340 Appliance
      1.  
        Configuring the storage
      2.  
        Configuring an S3 server
      3.  
        Activating an LTR policy
      4.  
        Generating S3 keys
      5.  
        Provisioning the storage
  5. Storage management
    1.  
      About the appliance storage
    2.  
      Viewing the storage on the appliance
    3.  
      Scanning the storage on the appliance
  6. Network connection management
    1. Configuring network address settings on the appliance nodes
      1.  
        About NIC1 (eth0) port usage on the appliance nodes
    2.  
      About VLAN tagging on the appliance
    3.  
      Configuring static routes on the appliance
    4.  
      Configuring DNS and host name mapping on the appliance
    5.  
      About the maximum transmission unit size on the appliance
    6. About the Veritas Remote Management Console
      1.  
        Configuring the IPMI port on an appliance node
      2.  
        Managing IPMI users on an appliance node
      3.  
        Resetting the IPMI on an appliance node
    7.  
      Setting the date and time on the appliance
  7. Monitoring the appliance
    1.  
      About hardware monitoring in the Access GUI
    2. About Veritas AutoSupport on the Access Appliance
      1.  
        Setting up AutoSupport on the appliance
      2.  
        Using a proxy server with the appliance
    3.  
      Setting up email notifications on the appliance
    4.  
      Setting up SNMP notifications on the appliance
    5.  
      Testing the appliance hardware
  8. Resetting the appliance to factory settings
    1.  
      About appliance factory reset
    2.  
      Performing a single node factory reset
    3.  
      Performing a full appliance cluster factory reset
  9. Appliance security
    1.  
      About Access Appliance security
    2. About Access appliance user account privileges
      1. Access appliance admin password specifications
        1.  
          Password encryption and handling on the Access appliance
    3.  
      Changing the Maintenance user account password
    4. About the Access Appliance intrusion detection system
      1.  
        Reviewing SDCS events on the Access Appliance
      2.  
        Auditing the SDCS logs on an Access Appliance
      3.  
        About SDCS event type codes and severity codes on an Access appliance node
      4.  
        Changing the SDCS log retention settings on an Access appliance node
    5. About Access appliance operating system security
      1.  
        Vulnerability scanning of the Access Appliance
      2.  
        Disabled service accounts on the Access appliance
    6.  
      About data security on the Access appliance
    7.  
      About data integrity on the Access appliance
    8. Recommended IPMI settings on the Access appliance
      1.  
        Replacing the default IPMI SSL certificate on the Access appliance
  10. Troubleshooting
    1.  
      About appliance log files
    2.  
      Viewing log files using the Support command
    3.  
      Gathering device logs with the DataCollect command

Resetting the IPMI on an appliance node

If the Veritas Remote Management Console stops responding, you can reset it using the Support > IPMI Reset command.

To reset the IPMI

  1. Log on to the Access Appliance shell menu.
  2. Run the following command:

    Support > IPMI Reset

  3. The following prompt displays:
     >> Resetting the IPMI disconnects all current IPMI users. 
    Are you sure you want to reset the IPMI? [yes, no]:

    Type yes and press Enter.

  4. The IPMI starts resetting in the background. Wait for 2 minutes before you attempt to reconnect to the Veritas Remote Management Console.
  5. If you cannot access the Veritas Remote Management Console after resetting the IPMI, perform the following steps:

    • Schedule a convenient time for the appliance node shutdown and alert all users.

    • Shut down the appliance node.

    • Disconnect all power cables to the appliance node.

    • Wait for 15 seconds and then reconnect the cables.

    • Turn on the appliance node.

See Configuring the IPMI port on an appliance node.

See Managing IPMI users on an appliance node.