Veritas Access Appliance Initial Configuration and Administration Guide
- Getting to know the Access Appliance
- Preparing to configure the appliance
- Configuring the appliance for the first time
- Getting started with the Veritas Access GUI
- Storage management
- Network connection management
- Configuring network address settings on the appliance nodes
- About the Veritas Remote Management Console
- Monitoring the appliance
- Resetting the appliance to factory settings
- Appliance security
- About Access appliance user account privileges
- About the Access Appliance intrusion detection system
- About Access appliance operating system security
- Recommended IPMI settings on the Access appliance
- Troubleshooting
Configuring the Access cluster on the appliance
This procedure configures the Veritas Access cluster on the appliance. This procedure is only performed during the initial configuration of the appliance. Ensure that you complete all of the other necessary steps in the initial configuration process before you configure the cluster.
See How to configure the Access Appliance for the first time.
To configure the Veritas Access cluster on the appliance
- Log on to the Access Appliance shell menu of one of the appliance nodes.
- From the Main_Menu > Manage > Cluster view, type the following command to start the cluster configuration wizard:
Configure
- Type yes to continue.
- Type the password of the Maintenance user of both nodes.
Note:
The Maintenance user password must be the same on each node or the configuration fails. To protect the security of the appliance, you should change the Maintenance user password of each node before you start the cluster configuration. You cannot change the Maintenance user password after the cluster is configured.
- Enter a name for the cluster.
Cluster names should be DNS-compatible. DNS-compliant cluster names should conform to the following naming conventions:
Must be at least three and no more than 63 characters long.
Allowed characters in a cluster name are lowercase letters, numbers, and hyphens 'a-z, 0-9, -'. Any other character is invalid.
Must start with a lowercase letter and must not start with a hyphen ('-') or number.
Must end with a lowercase letter or a number.
Should not be an IP address.
- Enter the eth1 IP addresses for each node, separated by a space.
- Enter the starting IP address of the four public IP addresses that you have reserved.
For example, if you type 10.182.12.89, the appliance will use 10.182.12.89-92 for public IP addresses.
- Enter the starting IP address of the four virtual IP addresses that you have reserved.
- Enter the netmask for the public IP addresses.
- Enter the default gateway IP address.
- Enter the DNS server IP address.
- Enter the DNS server domain name.
- Enter the console virtual IP address.
- Review the configuration checklist and type yes to continue and begin the configuration.
The configuration process can take around 40 minutes to complete.
- You are prompted to change the password of the admin user account. Type yes to change it.
Veritas recommends that you change the admin user account's password since it is a known default password. If you do not change this account's password now, you must do it later in the Access shell menu.
Once the configuration is complete, you have the ability to log into all of the user interfaces on the appliance.
Table: Appliance user interface addresses
Interface | IP address |
---|---|
Access Appliance shell menu for node 1 | Node 1 eth1 IP over SSH |
Access Appliance shell menu for node 2 | Node 2 eth1 IP over SSH |
Access shell menu | Console IP over SSH |
Access GUI | http://consoleIP:14161/ |
More Information