Arctera Data Insight Administrator's Guide
- Section I. Getting started
- Introduction to Arctera Data Insight administration
- Configuring Data Insight global settings
- About Data Insight licensing
- SQLite WAL mode
- Configuring SMTP server settings
- About scanning and event monitoring
- Monitoring Indexer Node Storage Utilization
- About filtering certain accounts, IP addresses, and paths
- About archiving data
- About Data Insight integration with Data Loss Prevention (DLP)
- Importing sensitive files information through CSV
- Configuring advanced analytics
- About open shares
- About user risk score
- Configuring file groups
- Configuring Workspace data owner policy
- Configuring Management Console settings
- About bulk assignment of custodians
- Configuring Watchlist settings
- Configuring Metadata Framework
- Proof of concept
- Section II. Configuring Data Insight
- Configuring Data Insight product users
- Configuring Data Insight product servers
- About Data Insight product servers
- Adding a new Data Insight server
- Managing Data Insight product servers
- Viewing Data Insight server details
- About node templates
- Adding Portal role to a Data Insight server
- Adding Classification Server role to a Data Insight server
- Assigning Classification Server to a Collector
- Associating a Classification Server pool to a Collector
- Viewing in-progress scans
- Configuring Data Insight services
- Configuring advanced settings
- Monitoring Data Insight jobs
- Rotating the encryption keys
- Viewing Data Insight server statistics
- About automated alerts for patches and upgrades
- Deploying upgrades and patches remotely
- Using the Upload Manager utility
- About migrating storage devices across Indexers
- Viewing the status of a remote installation
- Configuring saved credentials
- Configuring directory service domains
- About directory domain scans
- Adding a directory service domain to Data Insight
- Managing directory service domains
- Fetching users and groups data from NIS+ scanner
- Configuring attributes for advanced analytics
- Deleting directory service domains
- Scheduling scans
- Configuring business unit mappings
- Importing additional attributes for users and user groups
- Configuring containers
- Section III. Configuring native file systems in Data Insight
- Configuring NetApp 7-mode file server monitoring
- About configuring NetApp file server monitoring
- Prerequisites for configuring NetApp file servers
- Credentials required for configuring NetApp filers
- Credentials required for configuring NetApp NFS filers
- Configuring SMB signing
- About FPolicy
- Preparing Data Insight for FPolicy
- Preparing the NetApp filer for Fpolicy
- Preparing the NetApp vfiler for Fpolicy
- Configuring NetApp audit settings for performance improvement
- Preparing a non-administrator domain user on the NetApp filer for Data Insight
- Enabling export of NFS shares on a NetApp file server
- Excluding volumes on a NetApp file server
- Handling NetApp home directories in Data Insight
- Configuring clustered NetApp file server monitoring
- About configuring a clustered NetApp file server
- About configuring FPolicy in Cluster-Mode
- Pre-requisites for configuring clustered NetApp file servers
- Credentials required for configuring a clustered NetApp file server
- Preparing a non-administrator local user on the clustered NetApp filer
- Preparing a non-administrator domain user on a NetApp cluster for Data Insight
- Persistent Store
- Preparing Data Insight for FPolicy in NetApp Cluster-Mode
- Preparing the ONTAP cluster for FPolicy
- About configuring secure communication between Data Insight and cluster-mode NetApp devices
- Enabling export of NFS shares on a NetApp Cluster-Mode file server
- Enabling SSL support for Cluster Mode NetApp auditing
- Configuring EMC Celerra or VNX monitoring
- Configuring EMC Isilon monitoring
- About configuring EMC Isilon filers
- Prerequisites for configuration of Isilon or Unity VSA file server monitoring
- Credentials required for configuring an EMC Isilon cluster
- Configuring audit settings on EMC Isilon cluster using OneFS GUI console
- Configuring audit settings on EMC Isilon cluster using the OneFS CLI
- Configuring Isilon audit settings for performance improvement
- Preparing Arctera Data Insight to receive event notifications from an EMC Isilon or Unity VSA cluster
- Creating a non-administrator user for an EMC Isilon cluster
- Utilizing access zone's SmartConnect Zone/Alias mappings
- Purging the audit logs in an Isilon filer
- Configuring EMC Unity VSA file servers
- Configuring Hitachi NAS file server monitoring
- Configuring Windows File Server monitoring
- Configuring Veritas File System (VxFS) file server monitoring
- Configuring monitoring of a generic device
- Managing file servers
- About configuring filers
- Viewing configured filers
- Adding filers
- Add/Edit NetApp filer options
- Add/Edit NetApp cluster file server options
- Add/Edit EMC Celerra filer options
- Add/Edit EMC Isilon file server options
- Add/Edit EMC Unity VSA file server options
- Add/Edit Windows File Server options
- Add/Edit Veritas File System server options
- Add/Edit a generic storage device options
- Add/Edit Hitachi NAS file server options
- Custom schedule options
- Editing filer configuration
- Deleting filers
- Viewing performance statistics for file servers
- About disabled shares
- Adding shares
- Managing shares
- Editing share configuration
- Deleting shares
- About configuring a DFS target
- Adding a configuration attribute for devices
- Configuring a DFS target
- About the DFS utility
- Running the DFS utility
- Importing DFS mapping
- Renaming storage devices
- Configuring NetApp 7-mode file server monitoring
- Section IV. Configuring SharePoint data sources
- Configuring monitoring of SharePoint web applications
- About SharePoint server monitoring
- Credentials required for configuring SharePoint servers
- Configuring a web application policy
- About the Data Insight web service for SharePoint
- Viewing configured SharePoint data sources
- Adding web applications
- Editing web applications
- Deleting web applications
- Adding site collections
- Managing site collections
- Removing a configured web application
- Configuring monitoring of SharePoint Online accounts
- About SharePoint Online account monitoring
- Configuring user with minimum privileges in Microsoft 365
- Creating an application in the Microsoft Azure portal
- Configuring application without user impersonation for Microsoft 365
- Adding SharePoint Online accounts
- Managing a SharePoint Online account
- Adding site collections to SharePoint Online accounts
- Managing site collections
- Configuring monitoring of SharePoint web applications
- Section V. Configuring cloud data sources
- Configuring monitoring of Box accounts
- Configuring OneDrive account monitoring
- Configuring Azure Netapp Files Device
- Managing cloud sources
- Section VI. Configuring Object Storage Sources
- Section VII. Health and monitoring
- Section VIII. Alerts and policies
- Section IX. Remediation
- Configuring remediation settings
- Section X. Reference
- Appendix A. Data Insight best practices
- Appendix B. Migrating Data Insight components
- Appendix C. Backing up and restoring data
- Appendix D. Data Insight health checks
- About Data Insight health checks
- Services checks
- Deployment details checks
- Generic checks
- Data Insight Management Server checks
- Data Insight Indexer checks
- Data Insight Collector checks
- Data Insight Windows File Server checks
- Data Insight SharePoint checks
- Classification server health checks
- Data Insight self service portal server health checks
- About Data Insight health checks
- Appendix E. Command File Reference
- Appendix F. Data Insight jobs
- Appendix G. Troubleshooting
- About general troubleshooting procedures
- About the Health Audit report
- Location of Data Insight logs
- Downloading Data Insight logs
- Migrating the data directory to a new location
- Troubleshooting FPolicy issues on NetApp devices
- Troubleshooting EMC Celera or VNX configuration issues
- Troubleshooting EMC Isilon configuration issues
- Troubleshooting SharePoint configuration issues
- Troubleshooting Hitachi NAS configuration issues
- Troubleshooting installation of Tesseract software
- Troubleshooting RHEL 9 upgrade issue
Utilizing access zone's SmartConnect Zone/Alias mappings
EMC Isilon publishes shares through access zones. Access zones are virtual containers in which the Isilon cluster is partitioned. An access zone may be associated with an IP address pool. A pool is used to map an access zone with a SmartConnect zone and a range of IP addresses. The SmartConnect zone hostname and alias is typically used to discover shares instead of the access zone name. Data Insight discovers access zone to SmartConnect zone mapping and uses these names for scanning the shares. You must configure your preference when adding an Isilon filer to the Data Insight configuration. Ensure that access zone names are DNS resolvable.
From Data Insight 6.4, shares with same name belonging to different access zones will be disambiguated by prefixing <access_zone_name>@. The new share name will be one of the following:
\\<cmh>\<access_zone_name>@<share_name>, where cmh stands for Cluster Management Host.
\\<smartConnectZoneName>\<access_zone_name>@<share_name>
\\<SmartConnectZoneAliasName>\<access_zone_name>@<share_name>
Disambiguated CIFS shares and NFS exports will be visible in Work Space > Data Sources > Filer > Share list view and scanning, auditing, reporting and classification will be supported for those shares. If you have already configured inputs for reports and workflows in earlier versions of Data Insight, correct it as per the new format <access_zone_name>@<share_name>.
Note:
DFS mappings will not be created automatically for access zones configured using Cluster Management Host (CMH) in Data Insight. If you need those mappings, you will need to create it manually.
Following figure denotes configuration of Isilon filer to map SmartConnect zones names/SmartConnect zone aliases and to include access zone name as a part of share name.
Caution:
If you are upgrading to 6.4, your configured shares or exports from the earlier version will be mapped to the MSU corresponding to the access zone.
You will not be able to copy a clickable/resolvable path and paste it in the Go to bar.
Note:
Support for using SmartConnect to discover shares is available for Isilon OneFS version 8.0 and later.
You can also choose to input the alternate SmartConnect names against access zones mappings using a CSV file as input.
Points to remember while creating CSV file for bulk uploading EMC ISILON shares
Input should be inline with the chosen radio buttons. The available radio buttons in Access Zones Configuration are All access zones using cluster management host, Chosen access zones using cluster management host and Chosen access zones using smart connect zone name or smart connect zone alias.
In case of NFS exports, the export name must match exactly to the name added in the filer.
The CSV file must be placed in the directory DATADIR/conf on the Management server. The name of the CSV is isilon.csv. When DiscoverySharesJob_mrg runs the next time, it discovers and scans shares using alternate name provided in the CSV file.
After uploading the CSV file, run the jobs DiscoverShares_Job and DiscoverSharesJob_mrg to make sure that the things are inline with your selection of the radio button.