Veritas InfoScale 7.3.1 Installation and Upgrade Guide - Windows

Last Published:
Product(s): InfoScale & Storage Foundation (7.3.1)
Platform: Windows
  1. Preinstallation and planning
    1.  
      About the Veritas InfoScale product suite
    2.  
      Supported hardware and software
    3.  
      Disk space requirements
    4.  
      Installation requirements
    5.  
      Requirements for installing InfoScale Storage in a Microsoft Failover Cluster
    6.  
      Recommendations and best practices
    7. About InfoScale licenses
      1.  
        Licensing notes
      2.  
        vxlicrep command
  2. Installing the Veritas InfoScale products
    1.  
      About installing the InfoScale products
    2.  
      About the co-existence of InfoScale products
    3.  
      Installing the server components using the installation wizard
    4.  
      Applying the selected installation and product options to multiple systems
    5.  
      Installing the server components using the command-line installer
    6.  
      Parameters for Setup.exe
    7.  
      Available product options and supported DMP DSMs
    8.  
      Registering the InfoScale Storage resource DLLs
    9.  
      Installing the client components
  3. Upgrading to InfoScale products
    1. Preparing the systems for an upgrade
      1.  
        About the supported upgrade paths and the supported minimum product versions
      2.  
        General preparations
      3.  
        Recommendations and considerations for product upgrade
    2. Performing the product upgrade
      1. Upgrading SFW or SFW Basic in a non-clustered environment
        1.  
          Preparing the primary site for upgrade in a non-clustered SFW environment
      2. Upgrading SFW or SFW Basic in a Windows Server Failover Cluster environment
        1.  
          Preparing the secondary site for upgrade in a Windows Server Failover Cluster environment
        2.  
          Failing over application to secondary site
        3.  
          Preparing the primary site for upgrade in a Windows Server Failover Cluster environment
      3.  
        Upgrading VCS
      4. Upgrading SFW HA
        1.  
          Preparing the primary and secondary sites for upgrade in a Volume Replicator environment
        2.  
          Associating the replication logs and starting the replication
        3.  
          Re-enabling Volume Replicator in a VCS cluster
      5.  
        Upgrading DMP
    3.  
      About transitioning between the InfoScale products
  4. Performing the post upgrade tasks
    1.  
      Deployment scenarios and applicable post upgrade tasks
    2.  
      Re-enabling Volume Replicator in a non-clustered environment
    3.  
      Re-enabling Volume Replicator in a Microsoft failover cluster environment
    4.  
      Reconnecting DMP DSM paths after the upgrade
    5.  
      Reconfiguring the Veritas InfoScale Messaging Service
    6.  
      Importing the configured rules
    7.  
      Upgrading clusters for stronger security
    8.  
      Reinstalling the custom agents
    9.  
      Including custom resources
  5. Administering the InfoScale product installation
    1.  
      Adding or removing product options
    2.  
      Managing InfoScale licenses
    3.  
      Repairing an InfoScale product installation
    4.  
      About reinstalling InfoScale products
  6. Uninstalling the InfoScale products
    1.  
      About uninstalling the InfoScale products
    2.  
      Uninstalling the InfoScale products using the installation wizard
  7. Performing application upgrades in an InfoScale environment
    1. Upgrading Microsoft SQL Server
      1. Upgrading to later versions of SQL Server
        1.  
          Upgrading SQL Server on the first cluster node
        2.  
          Upgrading SQL Server on additional failover nodes
        3.  
          Creating the new SQL Server service group
    2. Upgrading Oracle
      1.  
        Performing the post upgrade tasks
      2.  
        Associating the updated Oracle database with the listener
      3. Configuring the Oracle database and listener to use the virtual IP address
        1.  
          Setting the dispatchers parameter in PFILE
        2.  
          Setting the dispatchers parameter in SPFILE
      4.  
        Configuring Oracle and listener services
      5.  
        Modifying the ServiceName attribute for the netlsnr resource
    3. Upgrading application service packs in an InfoScale environment
      1. Upgrading the Exchange Server service packs
        1.  
          Upgrading Exchange Server 2010 to a service pack
      2. Upgrading the SQL Server service packs
        1.  
          Upgrading SQL Server 2012 or SQL Server 2014 or SQL Server 2016 to a service pack
      3.  
        Upgrading SharePoint Server 2010 to a service pack
  8. Appendix A. Services and ports
    1.  
      InfoScale ports and services
  9. Appendix B. Migrating from a third-party multi-pathing solution to DMP
    1.  
      Migrating from EMC PowerPath
    2. Migrating from Hitachi Dynamic Link Manager (HDLM)
      1.  
        Uninstalling HDLM in a non-clustered environment
      2.  
        Uninstalling HDLM in a clustered (MSCS or VCS) environment
    3.  
      Configuring DMP for Active/Active load balancing in a cluster

Including custom resources

The product installer does not upgrade custom resources. If a service group in the previous configuration contains custom resources, the wizard does not include the service group in the upgraded cluster.

To include a service group with custom resources in the upgraded cluster

  1. Make sure that the agent binaries for the custom agent are available under %VCS_HOME%\bin where the variable %VCS_HOME% represents the VCS installation directory, typically C:\Program Files\Veritas\cluster server.
  2. Stop the VCS engine (HAD) on all the nodes in the cluster.

    From the command prompt, type:

    C:\> hastop -all -force
  3. During the installation, the installer copies previous configuration files to a backup location. Locate the backed up types.cf and main.cf files: C:\Documents and Settings\All Users\Application Data\Veritas\cluster server\vpibackup.
  4. Copy the resource type definition for the custom resource from the backed up types.cf and add it to the types.cf file for the VCS cluster.
  5. If resources for a custom resource type are dependent on resources for agents bundled with VCS, you must update the resource definition of the VCS bundled agent to include the new attributes or remove the deprecated attributes.

    For information on the attribute values and descriptions, see the Cluster Server Bundled Agents Reference Guide.

  6. Verify the configuration.

    From the command prompt, type:

    C:\> hacf -verify config_directory

    The variable config_directory refers to the path of the directory containing the main.cf and types.cf.

  7. Start the VCS engine (HAD) on the node where you changed the configuration. Type the following at the command prompt:
    C:\> hastart