  1. Introduction
    1.  
      About NetBackup commands
    2.  
      Navigating multiple menu levels
    3.  
      NetBackup command conventions
    4.  
      NetBackup Media Manager command notes
    5.  
      IPV6 updates
  2. Appendix A. NetBackup Commands
    1.  
      acsd
    2.  
      backupdbtrace
    3.  
      backuptrace
    4.  
      bmrc
    5.  
      bmrconfig
    6.  
      bmrepadm
    7.  
      bmrprep
    8.  
      bmrs
    9.  
      bmrsrtadm
    10.  
      bp
    11.  
      bparchive
    12.  
      bpbackup
    13.  
      bpbackupdb
    14.  
      bpcatarc
    15.  
      bpcatlist
    16.  
      bpcatres
    17.  
      bpcatrm
    18.  
      bpcd
    19.  
      bpchangeprimary
    20.  
      bpcleanrestore
    21.  
      bpclient
    22.  
      bpclimagelist
    23.  
      bpclntcmd
    24.  
      bpclusterutil
    25.  
      bpcompatd
    26.  
      bpconfig
    27.  
      bpdbjobs
    28.  
      bpdbm
    29.  
      bpdgclone
    30.  
      bpdown
    31.  
      bpduplicate
    32.  
      bperror
    33.  
      bpexpdate
    34.  
      bpfis
    35.  
      bpflist
    36.  
      bpgetconfig
    37.  
      bpgetdebuglog
    38.  
      bpimage
    39.  
      bpimagelist
    40.  
      bpimmedia
    41.  
      bpimport
    42.  
      bpinst
    43.  
      bpkeyfile
    44.  
      bpkeyutil
    45.  
      bplabel
    46.  
      bplist
    47.  
      bpmedia
    48.  
      bpmedialist
    49.  
      bpminlicense
    50.  
      bpnbat
    51.  
      bpnbaz
    52.  
      bppficorr
    53.  
      bpplcatdrinfo
    54.  
      bpplclients
    55.  
      bppldelete
    56.  
      bpplinclude
    57.  
      bpplinfo
    58.  
      bppllist
    59.  
      bpplsched
    60.  
      bpplschedrep
    61.  
      bpplschedwin
    62.  
      bppolicynew
    63.  
      bpps
    64.  
      bprd
    65.  
      bprecover
    66.  
      bprestore
    67.  
      bpretlevel
    68.  
      bpschedule
    69.  
      bpschedulerep
    70.  
      bpsetconfig
    71.  
      bpstsinfo
    72.  
      bpstuadd
    73.  
      bpstudel
    74.  
      bpstulist
    75.  
      bpsturep
    76.  
      bptestbpcd
    77.  
      bptestnetconn
    78.  
      bpup
    79.  
      bpverify
    80.  
      cat_convert
    81.  
      cat_export
    82.  
      cat_import
    83.  
      configureCerts
    84.  
      configureMQ
    85.  
      configureWebServerCerts
    86.  
      create_nbdb
    87.  
      csconfig cldinstance
    88.  
      csconfig cldprovider
    89.  
      csconfig meter
    90.  
      csconfig reinitialize
    91.  
      csconfig throttle
    92.  
      duplicatetrace
    93.  
      importtrace
    94.  
      jbpSA
    95.  
      jnbSA
    96.  
      ltid
    97.  
      mklogdir
    98.  
      msdpcldutil
    99.  
      msdpimgutil
    100.  
      nbauditreport
    101.  
      nbcallhomeproxyconfig
    102.  
      nbcatsync
    103.  
      NBCC
    104.  
      NBCCR
    105.  
      nbcertcmd
    106.  
      nbcertupdater
    107.  
      nbcldutil
    108.  
      nbcmdrun
    109.  
      nbcomponentupdate
    110.  
      nbcplogs
    111.  
      nbcredkeyutil
    112.  
      nbdb_admin
    113.  
      nbdb_backup
    114.  
      nbdb_move
    115.  
      nbdb_ping
    116.  
      nbdb_restore
    117.  
      nbdb_unload
    118.  
      nbdb2adutl
    119.  
      nbdbms_start_server
    120.  
      nbdbms_start_stop
    121.  
      nbdc
    122.  
      nbdecommission
    123.  
      nbdelete
    124.  
      nbdeployutil
    125.  
      nbdevconfig
    126.  
      nbdevquery
    127.  
      nbdiscover
    128.  
      nbdna
    129.  
      nbemm
    130.  
      nbemmcmd
    131.  
      nbepicfile
    132.  
      nbfindfile
    133.  
      nbfirescan
    134.  
      nbfp
    135.  
      nbftadm
    136.  
      nbftconfig
    137.  
      nbgetconfig
    138.  
      nbhba
    139.  
      nbholdutil
    140.  
      nbhostidentity
    141.  
      nbhostmgmt
    142.  
      nbhsmcmd
    143.  
      nbhypervtool
    144.  
      nbidpcmd
    145.  
      nbimageshare
    146.  
      nbinstallcmd
    147.  
      nbjm
    148.  
      nbkmiputil
    149.  
      nbkmscmd
    150.  
      nbkmsutil
    151.  
      nblogparser
    152.  
      nbmariadb
    153.  
      nbmysql
    154.  
      nbmlb
    155.  
      nborair
    156.  
      nboracmd
    157.  
      nbpem
    158.  
      nbpemreq
    159.  
      nbmariadb
    160.  
      nbmlb
    161.  
      nbperfchk
    162.  
      nbpgsql
    163.  
      nbplupgrade
    164.  
      nbrb
    165.  
      nbrbutil
    166.  
      nbreplicate
    167.  
      nbrepo
    168.  
      nbrestorevm
    169.  
      nbseccmd
    170.  
      nbserviceusercmd
    171.  
      nbsetconfig
    172.  
      nbshvault
    173.  
      nbsmartdiag
    174.  
      nbsnapimport
    175.  
      nbsnapreplicate
    176.  
      nbsqlcmd
    177.  
      nbsqlite
    178.  
      nbstl
    179.  
      nbstlutil
    180.  
      nbstop
    181.  
      nbsu
    182.  
      nbsvrgrp
    183.  
      netbackup_deployment_insights
    184.  
      resilient_clients
    185.  
      restoretrace
    186.  
      stopltid
    187.  
      tiermover
    188.  
      tldd
    189.  
      tldcd
    190.  
      tpautoconf
    191.  
      tpclean
    192.  
      tpconfig
    193.  
      tpext
    194.  
      tpreq
    195.  
      tpunmount
    196.  
      verifytrace
    197.  
      vltadm
    198.  
      vltcontainers
    199.  
      vlteject
    200.  
      vltinject
    201.  
      vltoffsitemedia
    202.  
      vltopmenu
    203.  
      vltrun
    204.  
      vmadd
    205.  
      vmchange
    206.  
      vmcheckxxx
    207.  
      vmd
    208.  
      vmdelete
    209.  
      vmoprcmd
    210.  
      vmphyinv
    211.  
      vmpool
    212.  
      vmquery
    213.  
      vmrule
    214.  
      vmupdate
    215.  
      vnetd
    216.  
      vssat
    217.  
      vwcp_manage
    218.  
      vxlogcfg
    219.  
      vxlogmgr
    220.  
      vxlogview
    221.  
      W2KOption

Name

acsd — Automated Cartridge System (ACS) daemon (UNIX) or process (Windows)

SYNOPSIS

acsd [-v]

 

On UNIX systems, the directory path to this command is /usr/openv/volmgr/bin/

On Windows systems, the directory path to this command is install_path\Volmgr\bin\

DESCRIPTION

acsd interfaces with Media Manager to mount and unmount tapes automatically that are under Automated Cartridge System (ACS) control. If the Media and Device Management of the Administration Console shows drives in an ACS robot, the ltid NetBackup Device Manager daemon or service (Windows) runs acsd. Stopping ltid stops acsd.

On UNIX systems, start or stop acsd independently of ltid by using /usr/openv/volmgr/bin/vmps or your server's ps command to identify the acsd process ID. Then enter the following commands:

kill acsd_pid
/usr/openv/volmgr/bin/acsd [-v] &

acsd performs its tasks by sending requests to the ACS storage server Interface process (acsssi). It communicates with the server that controls the ACS.

On Windows systems, acsd performs its tasks by sending requests to the STK LibAttach service, which communicates with the server that controls the ACS.

When the connection is established, acsd puts the ACS robot in the UP state and can mount and unmount tapes. If the connection cannot be established or ACS errors exist, acsd changes the robot to the DOWN state. In this state, acsd still runs and returns the robot to the UP state when the problem no longer exists.

Use the following to address and define drives in the Media Manager: ACS number, LSM number, Panel number, and Drive number.

Configure drive cleaning for ACS robots by using ACS library software. You cannot define the cleaning volumes by using Media Manager. In addition, you cannot use the tpclean command for cleaning operations on drives under ACS robotic control.

On UNIX systems, the Internet service port number for acsd must be in /etc/services. If you use NIS (Network Information Service), place the entry in this host's /etc/services file in the master NIS server database for services. The default service port number is 13702.

On Windows systems, the Internet service port number for acsd must be in %SystemRoot%\system32\drivers\etc\services. The default service port number is 13702.

Note:

This command applies only to the NetBackup Enterprise Server.

OPTIONS

-v

This option is used on UNIX systems only. It logs debug information using syslogd. If you start ltid with -v, acsd also starts with -v.

ERRORS

On UNIX systems, acsd returns an error message if a copy of acsd is in operation. Media Manager logs ACS and network errors to syslogd. Log entries are also made when the state changes between UP and DOWN. acsssi logs to a log file in the /usr/openv/volmgr/debug/acsssi directory.

On Windows systems, Media Manager logs ACS and network errors to the Windows application event log. Log entries are also made when the state changes between UP and DOWN.

SEE ALSO

See ltid.

See tpconfig.