Veritas NetBackup™ 命令参考指南

Last Published:
Product(s): NetBackup (8.1.1)
  1. 介绍
    1.  
      关于 NetBackup 命令
    2.  
      浏览多个菜单级别
    3.  
      NetBackup 命令约定
    4.  
      NetBackup 介质管理器命令说明
    5.  
      IPv6 更新
  2. 附录 A. NetBackup 命令
    1.  
      acsd
    2.  
      add_media_server_on_clients
    3.  
      backupdbtrace
    4.  
      backuptrace
    5.  
      bmrc
    6.  
      bmrconfig
    7.  
      bmrepadm
    8.  
      bmrprep
    9.  
      bmrs
    10.  
      bmrsrtadm
    11.  
      bp
    12.  
      bparchive
    13.  
      bpbackup
    14.  
      bpbackupdb
    15.  
      bpcatarc
    16.  
      bpcatlist
    17.  
      bpcatres
    18.  
      bpcatrm
    19.  
      bpcd
    20.  
      bpchangeprimary
    21.  
      bpclient
    22.  
      bpclimagelist
    23.  
      bpclntcmd
    24.  
      bpclusterutil
    25.  
      bpcompatd
    26.  
      bpconfig
    27.  
      bpdbjobs
    28.  
      bpdbm
    29.  
      bpdgclone
    30.  
      bpdown
    31.  
      bpduplicate
    32.  
      bperror
    33.  
      bpexpdate
    34.  
      bpfis
    35.  
      bpflist
    36.  
      bpgetconfig
    37.  
      bpgetdebuglog
    38.  
      bpimage
    39.  
      bpimagelist
    40.  
      bpimmedia
    41.  
      bpimport
    42.  
      bpinst
    43.  
      bpkeyfile
    44.  
      bpkeyutil
    45.  
      bplabel
    46.  
      bplist
    47.  
      bpmedia
    48.  
      bpmedialist
    49.  
      bpminlicense
    50.  
      bpnbat
    51.  
      bpnbaz
    52.  
      bppficorr
    53.  
      bpplcatdrinfo
    54.  
      bpplclients
    55.  
      bppldelete
    56.  
      bpplinclude
    57.  
      bpplinfo
    58.  
      bppllist
    59.  
      bpplsched
    60.  
      bpplschedrep
    61.  
      bppolicynew
    62.  
      bpps
    63.  
      bprd
    64.  
      bprecover
    65.  
      bprestore
    66.  
      bpretlevel
    67.  
      bpschedule
    68.  
      bpschedulerep
    69.  
      bpsetconfig
    70.  
      bpstsinfo
    71.  
      bpstuadd
    72.  
      bpstudel
    73.  
      bpstulist
    74.  
      bpsturep
    75.  
      bptestbpcd
    76.  
      bptestnetconn
    77.  
      bptpcinfo
    78.  
      bpup
    79.  
      bpverify
    80.  
      cat_convert
    81.  
      cat_export
    82.  
      cat_import
    83.  
      configurePorts
    84.  
      create_nbdb
    85.  
      csconfig cldinstance
    86.  
      csconfig cldprovider
    87.  
      csconfig meter
    88.  
      csconfig throttle
    89.  
      duplicatetrace
    90.  
      importtrace
    91.  
      jbpSA
    92.  
      jnbSA
    93.  
      ltid
    94.  
      manageClientCerts
    95.  
      mklogdir
    96.  
      nbauditreport
    97.  
      nbcatsync
    98.  
      NBCC
    99.  
      NBCCR
    100.  
      nbcertcmd
    101.  
      nbcertupdater
    102.  
      nbcldutil
    103.  
      nbcomponentupdate
    104.  
      nbcplogs
    105.  
      nbdb_admin
    106.  
      nbdb_backup
    107.  
      nbdb_move
    108.  
      nbdb_ping
    109.  
      nbdb_restore
    110.  
      nbdb_unload
    111.  
      nbdbms_start_server
    112.  
      nbdbms_start_stop
    113.  
      nbdc
    114.  
      nbdecommission
    115.  
      nbdelete
    116.  
      nbdeployutil
    117.  
      nbdevconfig
    118.  
      nbdevquery
    119.  
      nbdiscover
    120.  
      nbdna
    121.  
      nbemm
    122.  
      nbemmcmd
    123.  
      nbexecute
    124.  
      nbfindfile
    125.  
      nbfirescan
    126.  
      nbftadm
    127.  
      nbftconfig
    128.  
      nbgetconfig
    129.  
      nbhba
    130.  
      nbholdutil
    131.  
      nbhostidentity
    132.  
      nbhostmgmt
    133.  
      nbhypervtool
    134.  
      nbjm
    135.  
      nbkmsutil
    136.  
      nboraadm
    137.  
      nborair
    138.  
      nbpem
    139.  
      nbpemreq
    140.  
      nbperfchk
    141.  
      nbplupgrade
    142.  
      nbrb
    143.  
      nbrbutil
    144.  
      nbregopsc
    145.  
      nbreplicate
    146.  
      nbrestorevm
    147.  
      nbseccmd
    148.  
      nbsetconfig
    149.  
      nbsnapimport
    150.  
      nbsnapreplicate
    151.  
      nbsqladm
    152.  
      nbstl
    153.  
      nbstlutil
    154.  
      nbstop
    155.  
      nbsu
    156.  
      nbsvrgrp
    157.  
      resilient_clients
    158.  
      restoretrace
    159.  
      stopltid
    160.  
      tl4d
    161.  
      tl8d
    162.  
      tl8cd
    163.  
      tldd
    164.  
      tldcd
    165.  
      tlhd
    166.  
      tlhcd
    167.  
      tlmd
    168.  
      tpautoconf
    169.  
      tpclean
    170.  
      tpconfig
    171.  
      tpext
    172.  
      tpreq
    173.  
      tpunmount
    174.  
      verifytrace
    175.  
      vltadm
    176.  
      vltcontainers
    177.  
      vlteject
    178.  
      vltinject
    179.  
      vltoffsitemedia
    180.  
      vltopmenu
    181.  
      vltrun
    182.  
      vmadd
    183.  
      vmchange
    184.  
      vmcheckxxx
    185.  
      vmd
    186.  
      vmdelete
    187.  
      vmoprcmd
    188.  
      vmphyinv
    189.  
      vmpool
    190.  
      vmquery
    191.  
      vmrule
    192.  
      vmupdate
    193.  
      vnetd
    194.  
      vwcp_manage
    195.  
      vxlogcfg
    196.  
      vxlogmgr
    197.  
      vxlogview
    198.  
      W2KOption

名称

vmchange — 更改 EMM 数据库中的介质信息

大纲

vmchange [-h EMM_server | volume_database_host] -vg_res -rt robot_type -rn robot_number -rh robot_control_host -v volume_group

vmchange [-h EMM_server | volume_database_host] -res -m media_id -mt media_type -rt robot_type -rn robot_number -rh robot_control_host -v volume_group -rc1 rob_slot

vmchange [-h EMM_server | volume_database_host] -exp date -m media_id

vmchange [-h EMM_server | volume_database_host] -barcode barcode -m media_id [-rt robot_type]

vmchange [-h EMM_server | volume_database_host] -m media_id -vltcid vault_container_id

vmchange [-h EMM_server | volume_database_host] -barcode barcode -vltcid vault_container_id

vmchange [-h EMM_server | volume_database_host] -d "media_description" -m media_id

vmchange [-h EMM_server | volume_database_host] -p pool_number -m media_id

vmchange [-h EMM_server | volume_database_host] -maxmounts max_mounts -m media_id

vmchange [-h EMM_server | volume_database_host] -clean cleanings left -m media_id

vmchange [-h EMM_server | volume_database_host] -n num_mounts -m media_id

vmchange [-h EMM_server | volume_database_host] -new_mt media_type -m media_id

vmchange [-h EMM_server | volume_database_host] -new_rt robot_type -m media_id -rn robot_number

vmchange [-h EMM_server | volume_database_host] -new_v volume_group [-m media_id |{-b barcode -mt media_type -rt robot_type}]

vmchange [-h EMM_server | volume_database_host] -vltname vault_name -m media_id

vmchange [-h EMM_server | volume_database_host] -vltsent date -m media_id

vmchange [-h EMM_server | volume_database_host] -vltreturn date -m media_id

vmchange [-h EMM_server | volume_database_host] -vltslot vault_slot -m media_id

vmchange [-h EMM_server | volume_database_host] -vltsession vault_session_id -m media_id

vmchange -api_eject -map map_id:mapid:...:mapid | any -w [-h EMM_server | volume_database_host] -res -ml media_id:media_id: ...:media_id -rt robot_type -rn robot_number -rh robot_control_host [-v volume_group]

vmchange -multi_eject -w [-h EMM_server | volume_database_host] -res -ml media_id:media_id: ...:media_id -rt robot_type -verbose -rn robot_number -rh robot_control_host

vmchange -multi_inject -w [-h EMM_server | volume_database_host] -res -rt robot_type -verbose -rn robot_number -rh robot_control_host

vmchange [-h EMM_server | volume_database_host] -res -robot_info -verbose -rn robot_number -rt robot_type -rh robot_control_host

 

在 UNIX 系统上,此命令的目录路径为 /usr/openv/volmgr/bin/

在 Windows 系统上,此命令的目录路径为 install_path\Volmgr\bin\

描述

更改企业介质管理器数据库中的卷信息。

任何得到授权的用户均可运行此命令。

有关 NetBackup 授权的更多信息,请参考《NetBackup 安全和加密指南》。

选项

-h EMM_server | volume_database_host

此选项仅适用于 NetBackup Enterprise Server。

包含卷的相关信息的企业介质管理器数据库主机的名称。如果没有指定主机,默认情况下将使用配置的 EMM 服务器。

-vg_res

更改卷组所在的位置。

-rt robot_type

指定卷所在的机械手的类型。

NetBackup Enterprise Server 的有效机械手类型如下:

none、acs、tl4、tl8、tld、tlh、tlm

NetBackup 服务器的有效机械手类型如下:

none、tl4、tl8、tld

-rn robot_number

卷所在的机械手的唯一逻辑标识号。

-rh robot_control_host

主机的名称,该主机控制卷所在的机械手。

-v volume_group

卷组是标识位于相同物理位置的一系列卷的逻辑分组。

-res

更改卷所在的位置。

-m media_id

指定要更改的卷的介质 ID。

-mt media_type

指定要更改的卷的介质类型。

NetBackup Enterprise Server 的有效介质类型如下:

4mm、8mm、8mm2、8mm3、dlt、dlt2、dlt3、dtf、hcart、hcart2、hcart3、qcart、4mm_clean、8mm_clean、8mm2_clean、8mm3_clean、dlt_clean、dlt2_clean、dlt3_clean、dtf_clean、hcart_clean、hcart2_clean、hcart3_clean

NetBackup 服务器的有效介质类型如下:

4mm、8mm、dlt、hcart、qcart、4mm_clean、8mm_clean、dlt_clean、hcart_clean

-rc1 rob_slot

机械手坐标 1 是卷所在的机械手插槽号。

以下说明仅适用于 NetBackup Enterprise Server:

不要输入 API 机械手类型的插槽信息。机械手软件将跟踪这些机械手的插槽位置。

-exp date

该卷的截止日期。

NetBackup 命令所需要的日期和时间值格式因区域设置的不同而不同。/usr/openv/msg/.conf 文件 (UNIX) 和 install_path\VERITAS\msg\LC.CONF 文件 (Windows) 包含诸如每个所支持的区域设置的日期时间格式等信息。这些文件包含有关如何添加或修改所支持的区域设置和格式列表的具体说明。

有关更多信息,请参见《NetBackup 管理指南,第 II 卷》中的“关于指定 NetBackup 安装的区域设置”主题。

-barcode barcode

指定附加到卷上的条形码。

-d "media_description"

卷的介质描述。如果描述中包含任何空格,则需要加上双引号。

-p pool_number

包含此卷的卷池的索引。可以使用 vmpool -listall 来获取池索引。

-maxmounts max_mounts

该卷最多可允许的装入次数。只用于非清洗介质。

-n num_mounts

对于非清洗介质,num_mounts 是装入该卷的次数。

-clean cleanings_left

对于清洗介质,cleanings_left 是该清洗磁带的剩余清洗次数。

-new_mt media_type

指定要更改的卷的介质类型。有关介质类型的列表,请参见 -mt 选项。

-new_rt robot_type

指定机械手类型。有关机械手类型的列表,请参见 -rt 选项。

-new_v volume_group

卷组是标识位于相同物理位置的一系列卷的逻辑分组。

-b barcode

指定附加到卷上的条形码。

-vltcid vault_container_id

更改存储卷的容器。vault_container_id(一个字符串,最多包含 29 个字母数字字符)用于指定该卷的新容器。可以使用 -m-barcode 选项来指定卷。

-vltname vault_name

指定为弹出卷的机械手配置的逻辑保管库的名称。

-vltsent date

指定将卷发送到场外的日期。

date 的格式取决于用户的区域设置。对于 C 区域设置,日期语法如下所示:

mm/dd/yyyy [hh[:mm[:ss]]]

-vltreturn date

指定曾请求从保管库供应商返回卷的日期。对于目录库备份卷,这是将请求从保管库供应商返回卷的日期。

NetBackup 命令所需要的日期和时间值格式因区域设置的不同而不同。/usr/openv/msg/.conf 文件 (UNIX) 和 install_path\VERITAS\msg\LC.CONF 文件 (Windows) 包含诸如每个所支持的区域设置的日期时间格式等信息。这些文件包含有关如何添加或修改所支持的区域设置和格式列表的具体说明。

有关更多信息,请参见《NetBackup 管理指南,第 II 卷》中的“关于指定 NetBackup 安装的区域设置”主题。

-vltslot vault_slot

为该卷占用的插槽指定保管库供应商的插槽号。

-vltsession vault_session_id

指定弹出该介质的保管库会话的 ID。

-api_eject

从指定的机械手中弹出 ACS、TLH 或 TLM 卷。对于 ACS 和 TLM 机械手,弹出超时期限为一周。对于 TLH 机械手,机械手对删除介质的期限没有限制。

-map map_id:mapid: ...:mapid | any

对于 ACS 机械手,此选项可以指定多个用于弹出操作的介质访问端口 (MAP)。map_id(也称作 CAP ID)可以是 all,也可以是 ALL,用于指定机械手中的所有 MAP。或者,它也可以是以冒号分隔的 ACS、LSM、CAP 格式的 MAP ID 列表。在使用 -map 选项时,将介质弹出到使用近似 MAP 算法指定的 MAP。该算法假定 LSM 为线性连接。

对于 TLM 机械手,使用 map_id ANY 弹出到为 DAS/SDLC 服务器上的每个介质类型配置的 MAP。

对于 TLH 机械手,选择“标准”MAP 或 BULK MAP,具体取决于库的硬件配置。

-w

等候标志。该标志必须与弹出、多个弹出和多个弹入命令一起使用。

-verbose

选择详细模式。

-ml media_id:media_id: ...:media_id

指定要从机械手中弹出的介质的列表。

-multi_eject

使用磁带库的介质访问端口来弹出多个卷。此选项仅对 TL8 和 TLD 机械手类型有效。弹出超时期限为 30 分钟。

-multi_inject

使用磁带库的介质访问端口来弹入多个卷。此选项仅对 TL8 和 TLD 机械手类型有效。此操作完成后,用户必须运行 vmupdate 命令以更新 EMM 数据库。

-robot_info

检索有关磁带库的信息。此选项仅对 TLD 和 TL8 机械手类型有效。

  • 字段 1 = 插槽数

  • 字段 2 = 邮件插槽数

  • 字段 3 = 驱动器数

  • 字段 4 = 机械手类型和子类型(如 tld -> 0)

  • 字段 5 = 条形码读取器。如果此机械手设备上装有条形码读取器,此字段将包含下列字符串:This robot has a barcode reader。

  • 字段 6 = 起始插槽

  • 字段 7 = 结束插槽

  • 字段 8 = 主查询字符串(如 HP~~~~~~C6240-8000~~~~~~2912)

警告

某些磁带库为其介质访问端口实现不同的功能。例如,某些库的前面板弹入和弹出功能与 NetBackup 中使用的介质访问端口 (例如 Spectra Logic Bullfrog)冲突。有些库则要求在使用介质访问端口(如 Spectra Logic Gator)时进行前面板交互。

出现以下情况时,介质将返回到(弹入到)机械手中: 使用弹出选项、未删除介质以及发生超时。如果出现此操作,应该清点机械手,然后弹出返回到机械手中的介质。

请务必阅读磁带库的操作员手册,以了解其介质访问端口功能。如果处理不当,某些库(如上述库)可能无法与 NetBackup 的弹入和弹出功能完全兼容, 而其他库可能完全不兼容。此外,NetBackup 还对这些选项参数执行有限验证。

示例

示例 1 - 更改卷 AJS100 的截止日期:

# vmchange -exp 12/31/12 23:59:59 -m AJS100

示例 2 - 将包含卷 AJS999 的池更改为池 1(NetBackup 池):

# vmchange -p 1 -m AJS999

示例 3 - 从第 700 号 ACS 机械手中弹出卷 abc123abc124。这两个卷的驻留位置将更改为独立驱动器。

# vmchange -res -api_eject -w -ml abc123:abc124 -rt acs -rn 700 -rh 
verbena -map 0,0,0

示例 4 - 更改卷 ABC123 的容器 ID:

# vmchange -vltcid Container001 -m ABC123

另请参见

请参见vmadd(1m)。

请参见vmdelete(1m)。

请参见vmpool(1m)。

请参见vmquery(1m)。