Cluster Server 7.4.2 Configuration and Upgrade Guide - Linux
- Section I. Configuring Cluster Server using the script-based installer
- I/O fencing requirements
- Preparing to configure VCS clusters for data integrity
- About planning to configure I/O fencing
- Setting up the CP server
- Configuring VCS
- Configuring a secure cluster node by node
- Completing the VCS configuration
- Verifying and updating licenses on the system
- Configuring VCS clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Setting up server-based I/O fencing using installer
- Section II. Automated configuration using response files
- Performing an automated VCS configuration
- Performing an automated I/O fencing configuration using response files
- Section III. Manual configuration
- Manually configuring VCS
- Configuring LLT manually
- Configuring VCS manually
- Configuring VCS in single node mode
- Modifying the VCS configuration
- Manually configuring the clusters for data integrity
- Setting up disk-based I/O fencing manually
- Setting up server-based I/O fencing manually
- Configuring server-based fencing on the VCS cluster manually
- Setting up non-SCSI-3 fencing in virtual environments manually
- Setting up majority-based I/O fencing manually
- Manually configuring VCS
- Section IV. Upgrading VCS
- Planning to upgrade VCS
- Performing a VCS upgrade using the installer
- Tasks to perform after upgrading to 2048 bit key and SHA256 signature certificates
- Performing an online upgrade
- Performing a phased upgrade of VCS
- About phased upgrade
- Performing a phased upgrade using the product installer
- Performing an automated VCS upgrade using response files
- Planning to upgrade VCS
- Section V. Adding and removing cluster nodes
- Adding a node to a single-node cluster
- Adding a node to a single-node cluster
- Adding a node to a multi-node VCS cluster
- Manually adding a node to a cluster
- Setting up the node to run in secure mode
- Configuring I/O fencing on the new node
- Adding a node using response files
- Removing a node from a VCS cluster
- Removing a node from a VCS cluster
- Removing a node from a VCS cluster
- Adding a node to a single-node cluster
- Section VI. Installation reference
- Appendix A. Services and ports
- Appendix B. Configuration files
- Appendix C. Configuring LLT over UDP
- Using the UDP layer for LLT
- Manually configuring LLT over UDP using IPv4
- Manually configuring LLT over UDP using IPv6
- About configuring LLT over UDP multiport
- Appendix D. Configuring LLT over TCP
- Manually configuring LLT over TCP using IPv4
- Manually configuring LLT over TCP using IPv6
- Appendix E. Migrating LLT links from IPv4 to IPv6 or dual-stack
- Appendix F. Using LLT over RDMA
- Configuring LLT over RDMA
- Configuring RDMA over an Ethernet network
- Configuring RDMA over an InfiniBand network
- Tuning system performance
- Manually configuring LLT over RDMA
- Troubleshooting LLT over RDMA
- Appendix G. Configuring the secure shell or the remote shell for communications
- Appendix H. Installation script options
- Appendix I. Troubleshooting VCS configuration
- Appendix J. Sample VCS cluster setup diagrams for CP server-based I/O fencing
- Appendix K. Upgrading the Steward process
To tune the LLT variables for I/O shipping
Append the /etc/sysconfig/llt
file with the following value:
To enable parallel ports for I/O shipping:
LLT_NMULTIPORTS = number of ports
If you set the value to 0 or 1, CVM uses only one port for I/O shipping.
To set number of threads per I/O shipping port:
LLT_RDLV_MTFACTOR = number of threads
If LLT_NMULTIPORTS = 0, the total number of threads for I/O shipping on the single port is 2. However, for performance reason, it is recommended that you set the number of threads to 8 or 16.
To get the total number of ports, including parallel ports, registered with LLT:
Use the lltstat -p command
Note that this command does not provide information about which ports used as parallel ports.
To get the number of ports used as parallel port for I/O shipping:
Use the lltstat -c command