About the System Status LED states
The System Status LED is a bi-color (Green/Amber) indicator that shows the current health of the system. The appliance provides two locations for this feature. The first location is on the Front Control Panel, while the second location is on the back edge of the server board.
Table: System Status LED states
Color | State | Criticality | Description |
---|---|---|---|
No color | Off - The system is not operating. | Not ready |
|
Green | Solid on (SO) | Healthy | Indicates that the system is running (in S0 State) and its status is "Healthy". The system does not exhibit any errors. AC power is present and BMC has started and manageability functionality is up and running. |
Green | ~1-Hz blinking | Degraded The system is operating in a degraded state although still functional. or The system is operating in a redundant state but with an impending failure warning. | System degraded:
|
Green | ~1-Hz blinking | Degraded The system is operating in a degraded state although still functional. or The system is operating in a redundant state but with an impending failure warning. | System degraded: (continued)
|
Amber | ~1-Hz blinking | Non-critical The system is operating in a degraded state with an impending failure warning. However, the system is still functioning. | Non-fatal, although the system is likely to fail due to the following issues:
|