Veritas NetBackup™ Administrator's Guide, Volume II
- NetBackup licensing models and usage reporting
- How capacity licensing works
- Creating and viewing the licensing report
- Reviewing a capacity licensing report
- Reconciling the capacity licensing report results
- Reviewing a traditional licensing report
- Reviewing an NEVC licensing report
- Additional configuration
- About dynamic host name and IP addressing
- About busy file processing on UNIX clients
- About the Shared Storage Option
- DELETE About configuring the Shared Storage Option in NetBackup
- Viewing SSO summary reports
- About the vm.conf configuration file
- Holds Management
- Menu user interfaces on UNIX
- About the tpconfig device configuration utility
- About the NetBackup Disk Configuration Utility
- Reference topics
- Host name rules
- About reading backup images with nbtar or tar32.exe
- Factors that affect backup time
- NetBackup notify scripts
- Media and device management best practices
- About TapeAlert
- About tape drive cleaning
- How NetBackup reserves drives
- About SCSI persistent reserve
- About the SPC-2 SCSI reserve process
- About checking for data loss
- About checking for tape and driver configuration errors
- How NetBackup selects media
- About Tape I/O commands on UNIX
TapeAlert logs and codes
TapeAlert codes are derived from the T10 SCSI-3 Stream Commands standard (see http://t10.org/). For the list of codes that the device supports, see the device's documentation.
TapeAlert checks for errors of the following types:
Recoverable read and write drive problems
Unrecoverable read and write drive problems
Hardware defects
Wrong or worn-out media
Expired cleaning tapes
Abnormal errors
A set of TapeAlert conditions is defined that can cause the media in use to be frozen. Another set of conditions are defined that can cause a drive to be downed.
NetBackup writes TapeAlert conditions into the following logs:
The bptm log
The error log
The job details log
The system log on UNIX and Event Viewer on Windows
The following table describes the codes.
Table: TapeAlert log codes
TapeAlert code | Default action | Error type | Error message |
---|---|---|---|
0x01 |
None |
Warning - WRN |
Read warning |
0x02 |
None |
Warning - WRN |
Write warning |
0x03 |
None |
Warning - WRN |
Hard error |
0x04 |
Freeze media - FRZ |
Critical - CRT |
Media |
0x05 |
Freeze media - FRZ |
Critical - CRT |
Read failure |
0x06 |
Freeze media - FRZ |
Critical - CRT |
Write failure |
0x07 |
Freeze media - FRZ |
Warning - WRN |
Media life |
0x08 |
Freeze media - FRZ |
Warning - WRN |
Not data grade |
0x09 |
None |
Critical - CRT |
Write protect |
0x0a |
None |
Informational - INFO |
No removal |
0x0b |
None |
Informational - INFO |
Cleaning media |
0x0c |
None |
Informational - INFO |
Unsupported format |
0x0d |
Freeze media - FRZ |
Critical - CRT |
Recoverable mechanical cartridge failure |
0x0e |
Freeze media - FRZ |
Critical - CRT |
Unrecoverable mechanical cartridge failure |
0x0f |
Freeze media - FRZ |
Warning - WRN |
Mic failure |
0x10 |
None |
Critical - CRT |
Forced eject |
0x11 |
None |
Warning - WRN |
Read only |
0x12 |
None |
Warning - WRN |
Directory corrupted on load |
0x13 |
Freeze media - FRZ |
Informational - INFO |
Nearing media life |
0x14 |
Clean drive - CLN |
Critical - CRT |
Clean now |
0x15 |
Clean drive - CLN |
Warning - WRN |
Clean periodic |
0x16 |
Freeze media - FRZ |
Critical - CRT |
Expired cleaning media |
0x17 |
Freeze media - FRZ |
Critical - CRT |
Invalid cleaning tape |
0x18 |
None |
Warning - WRN |
Retension requested |
0x19 |
None |
Warning - WRN |
Dual-port error |
0x1a |
None |
Warning - WRN |
Cooling fan failure |
0x1b |
None |
Warning - WRN |
Power supply failure |
0x1c |
None |
Warning - WRN |
Power consumption |
0x1d |
None |
Warning - WRN |
Drive maintenance |
0x1e |
Down drive - down |
Critical - CRT |
Hardware A |
0x1f |
Down drive - DOWN |
Critical - CRT |
Hardware B |
0x20 |
None |
Warning - WRN |
Interface |
0x21 |
None |
Critical - CRT |
Eject media |
0x22 |
None |
Warning - WRN |
Download fail |
0x23 |
None |
Warning - WRN |
Drive humidity |
0x24 |
None |
Warning - WRN |
Drive temperature |
0x25 |
None |
Warning - WRN |
Drive voltage |
0x26 |
None |
Critical - CRT |
Predictive failure |
0x27 |
None |
Warning - WRN |
Diagnostics req. |
0x28 - 0x31 |
None |
Informational - INFO |
Undefined |
0x32 |
None |
Warning - WRN |
Lost statistics |
0x33 |
Freeze media - FRZ |
Warning - WRN |
Directory invalid on unload |
0x34 |
Freeze media - FRZ |
Critical - CRT |
System area write failure |
0x35 |
Freeze media - FRZ |
Critical - CRT |
System area read failure |
0x36 |
Freeze media - FRZ |
Critical - CRT |
No start of data |
0x37 |
Freeze media - FRZ |
Critical - CRT |
Loading failure |
0x38 |
Freeze media - FRZ |
Critical - CRT |
Unrecoverable unload failure |
0x39 |
None |
Critical - CRT |
Automation interface failure |
0x3a |
None |
Warning - WRN |
Firmware failure |
0x3d - 0x40 |
None |
Informational - info |
Undefined |