Veritas NetBackup™ 5240 Appliance Product Description
- About the NetBackup 5240 Appliance
- NetBackup Appliance overview
- Features and components of the NetBackup Appliance
- NetBackup Appliance front panel disk drive configurations
- NetBackup Appliance front panel USB port
- NetBackup Appliance control panel
- NetBackup Appliance rear panel
- NetBackup Appliance I/O configuration options
- NetBackup Appliance total I/O on-board and PCIe ports
- Customizable I/O configurations by slot for existing NetBackup Appliance installations
- Dual-port 10 Gb Ethernet card with SFP+ transceiver ports
- QLE8442 dual-port 10Gb Ethernet/iSCSI capable card with SFP+ modules
- QLE2562 dual-port 8Gb Fibre Channel host bus adapter with SFP+ modules
- SAS tape-out adapter
- NetBackup Appliance Network Interface Port locations and speeds
- NetBackup Appliance I/O configuration options
- About the Veritas 2U12 49TB Storage Shelf
- NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf cables
- Appendix A. Technical specifications and compliance standards
- NetBackup Appliance and Veritas 2U12 49TB Storage Shelf technical specifications
- Environmental specifications
- Protocol standards
- Regulatory, compliance, and certification information
- Index
Environmental specifications
The following table lists the environmental specifications for the NetBackup Appliance and the Veritas 2U12 Storage Shelf.
Table: NetBackup Appliance and Veritas 2U12 Storage Shelf environmental specifications
Specification | NetBackup Appliance / Veritas 2U12 Storage Shelf |
|---|---|
Operating temperature | ASHRAE A2 (10°C to 35°C ) (50°F to 95°F) |
Non-operating temperature | -25°C to 70°C (-13°F to 158°F) The non-operating temperature is defined as the temperature of the system when the system is turned off. It is also referred to as the storage temperature. Veritas recommends that you do not store the system in an environment where the temperatures fall outside of the listed temperature range. |
Operating humidity (Relative Humidity) | 20% RH to 80% RH |
Non-operating humidity | 8% RH to 90% RH |
Operating altitude | -30 to 3000 m with ASHRAE A2 class derating (0 to 10,000 ft) |
Temperature gradient | 10°C/hour (50°F/hour) |
See NetBackup Appliance and Veritas 2U12 49TB Storage Shelf technical specifications.