Performing a single node factory reset
To start a single node factory reset, you need to remove the appliance node from the cluster before you reset the node. Use the Access shell menu to remove the node, and then physically disconnect the Ethernet cables connecting the node to the cluster.
For more information about Veritas Access commands, refer to the Veritas Access Appliance Command Reference Guide.
Note:
Do not reset the storage if you only want to reset a single node and preserve the cluster.
To perform a single node factory reset
- Log on to the Access Appliance shell menu.
- Enter the command Main_Menu > Support > FactoryReset.
The screen layout shows, and it requires you to answer the following questions before the factory reset begins.
>> Do you want to reset the network configuration as part of the factory reset? [yes, no](yes) no Select storage configuration and data reset [Optional] - Removes all data and backup images from the attached storage. - Resets the storage partitions. - [WARNING] Do not reset the storage unless you plan to factory reset the entire cluster. If you are resetting the entire cluster: Select 'no' when you are resetting the first node. Select 'yes' when you are resetting the last node. >> Do you want to reset the storage configuration and delete the data on the attached storage as part of the factory reset? (Select 'no' if you are resetting just a single node and want to preserve the cluster.) [yes, no](no) no >> A system restart is required to complete the factory reset. Do you want to automatically restart the node at the end of the factory reset process? [yes, no](no) yes
Note:
A known issue exists with selecting to not automatically restart the appliance. Veritas strongly recommends that you restart the appliance node at the end of the factory reset process. Refer to the Veritas Access Release Notes for more information about the known issue.
- After you respond to these questions, the summary information displays.
- The following warning appears. If you want to begin the factory reset operation, enter yes.
>> WARNING: The node is ready for factory reset. This process cannot be reversed! Do you want to proceed? [yes, no] (no) yes
The factory reset continues and info messages are shown. It takes about 20 minutes to complete the factory reset process.
- If you elected to reset the network configuration, you can no longer reach the Access Appliance shell menu over eth1. You must reconnect to the Access Appliance shell menu over IPMI.
Note:
Once the factory reset is complete, you may need to install software release updates or EEB packages on the appliance node before you add the node back into the cluster. This is to ensure that the two nodes have the same software version, and install the same EEB packages. For more information about cluster commands, refer to the Veritas Access Command Reference Guide.