Veritas NetBackup™ Appliance Troubleshooting Guide

Last Published:
Product(s): Appliances (3.0)
  1. About using the Troubleshooting Guide
    1.  
      About this guide
    2.  
      About the intended audience
    3.  
      About contacting Technical Support
    4.  
      About troubleshooting the NetBackup Appliance
  2. Best practices
    1.  
      About best practices
    2.  
      Determining the NetBackup Appliance serial number
    3.  
      About Fibre Channel HBA card configuration verification
    4.  
      About Notification settings
    5.  
      About IPMI configuration
    6.  
      About password management and recovery
    7.  
      About IPv4-IPv6-based network support
    8.  
      About enabling BMR options
    9.  
      About deleting users
  3. About troubleshooting tools
    1.  
      Tools for troubleshooting the NetBackup Appliance
    2.  
      About hardware monitoring
    3.  
      Troubleshooting and tuning appliance from the Appliance Diagnostics Center
    4. About NetBackup support utilities
      1.  
        NetBackup Domain Network Analyzer (NBDNA)
      2.  
        NetBackup Support Utility (NBSU)
  4. Working with log files
    1.  
      About NetBackup Appliance log files
    2.  
      About the Collect Log files wizard
    3.  
      Viewing log files using the Support command
    4.  
      Where to find NetBackup Appliance log files using the Browse command
    5.  
      Gathering device logs with the DataCollect command
    6.  
      About gathering information for NetBackup-Java applications
    7.  
      Enabling and disabling VxMS logging
  5. Disaster recovery
    1.  
      About disaster recovery
    2.  
      Disaster recovery best practices
    3. Disaster recovery scenarios
      1. Appliance sustained power interruption
        1.  
          Restoring operation to a NetBackup Appliance following a power outage
        2.  
          Restoring operation to a NetBackup Appliance with external storage following a power outage
      2. Appliance hardware failure
        1.  
          Removing and replacing hardware components
        2.  
          Setting a NetBackup 5330 storage shelf component to the Service Allowed mode
      3.  
        Complete loss of appliance with recoverable operating system drives and attached storage disks
      4. Complete loss of appliance with recoverable attached storage disks
        1.  
          Reimaging a NetBackup appliance from the USB drive
        2.  
          Reconfiguring a 52xx master server appliance using the NetBackup Appliance Shell Menu
        3.  
          Configuring a master server to communicate with an appliance media server
        4.  
          Reconfiguring a 52xx or 5330 media server appliance using the NetBackup Appliance Shell Menu
        5.  
          About NIC1 (eth0) port usage on NetBackup appliances
      5.  
        Complete loss of appliance and attached storage disks
      6.  
        NetBackup Appliance software corruption
      7. NetBackup Appliance database corruption
        1.  
          Rollback to an appliance checkpoint from the appliance shell menu
        2.  
          About appliance rollback validation
      8. NetBackup Appliance catalog corruption
        1.  
          Starting a factory reset from the appliance shell menu
      9.  
        NetBackup Appliance operating system corruption
  6. NetBackup Appliance error messages
    1.  
      About NetBackup Appliance error messages
    2.  
      Error messages displayed during initial configuration
    3.  
      Error messages displayed on the NetBackup Appliance Web Console
    4.  
      Error messages displayed on the NetBackup Appliance Shell Menu
    5.  
      NetBackup status codes applicable for NetBackup Appliance

About Fibre Channel HBA card configuration verification

The NetBackup Appliance server can be ordered with up to six Fibre Channel (FC) HBA cards already installed. Each card includes two standard Fibre Channel ports. You can configure a Fibre Channel HBA card on the appliance as Fibre Transport media server to use with SAN clients, or as a target host for optimized duplication and Auto Image Replication over FC.

Note:

Veritas does not support reconfiguring the FC HBA cards in the appliance rear panel. Do not switch cards in different slots or install a used card from another appliance without contacting Veritas Technical Support.

After you configure the Fibre Channel HBA cards, you may want to verify that it is configured properly. To do that, use the Main_Menu > Manage > FibreChannel > Show command from the command line interface. When you run the Main_Menu > Manage > FibreChannel > Show command and the HBA card was configured properly, you see an output that is similar to the following:

Testsys.FC> Show
FC HBA card(s) are configured correctly.

**** FC HBA Cards ****
02:00.0 Fibre Channel: QLogic Corp. ISP2432-based 4Gb Fibre Channel
to PCI Express HBA (rev 03)
02:00.1 Fibre Channel: QLogic Corp. ISP2432-based 4Gb Fibre Channel
to PCI Express HBA (rev 03)
03:00.0 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel
to PCI Express HBA (rev 02)
03:00.1 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel
to PCI Express HBA (rev 02)
06:00.0 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel
to PCI Express HBA (rev 02)
06:00.1 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel
to PCI Express HBA (rev 02)

**** Drivers ****
qla2xxx     is loaded
windrvr6    is loaded

**** Ports ****
Bus ID Slot  Port WWN     Status     Mode       Speed  Remote Ports
2:00.0 Slot3 21:00:...:07 Linkdown   Initiator  4 gb/s
2:00.1 Slot3 21:01:...:07 Linkdown   Initiator  4 gb/s
3:00.0 Slot2 21:00:...:30 Disconnect Target     8 gb/s
3:00.1 Slot2 21:00:...:31 Online     Initiator  2 gb/s 0x21000024...
6:00.0 Slot1 21:00:...:82 Fabric     Target     8 gb/s
6:00.1 Slot1 21:00:...:83 Online     Initiator  8 gb/s 0x21000024...

*** Devices ****
Device   Vendor   Host         Type               Remote Port
/dev/sg0 VERITAS  10.182.0.209 FCPIPE  (NBU 50x0) 0x21000024ff232438
/dev/sg2 VERITAS  10.182.0.209 FCPIPE  (NBU 50x0) 0x21000024ff3162be

*** Notes ****
(NOTE: Ports in mode "Initiator*" are configured for target mode
When SAN Client FT Media Server is active, however, are currently