请输入搜索词进行查询
搜索 <book_title>...
Veritas NetBackup™ Appliance 命令参考指南
Last Published:
2017-12-04
Product(s):
Appliances (3.1 (5340), 3.1 (5330), 3.1 (5240), 3.1 (5230), 3.1 (5220))
- 概述
- 附录 A. Main > Appliance 命令
- 附录 B. Main > Manage > FibreChannel 命令
- 附录 C. Main > Manage > HighAvailability 命令
- 附录 D. Main > Manage > Libraries 命令
- 附录 E. Main > Manage > Libraries > Advanced > ACS 命令
- 附录 F. Main > Manage > License 命令
- 附录 G. Main > Manage > MountPoints 命令
- 附录 H. Main > Manage > NetBackup CLI 命令
- 附录 I. Main > Manage > OpenStorage 命令
- 附录 J. Main > Manage > Software 命令
- 附录 K. Main > Manage > Storage 命令
- 附录 L. Main > Manage > Tapes 命令
- 附录 M. Main > Manage > Certificates 命令
- 附录 N. Main > Monitor 命令
- 附录 O. Main > Network 命令
- 附录 P. Main > Network > Security (IPsec) 命令
- 附录 Q. Main > Reports 命令
- 附录 R. Main > Settings 命令
- 附录 S. Main > Settings > Alerts 命令
- 附录 T. Main > Settings > Notifications 视图命令
- 附录 U. Main > Settings > Security 命令
- 附录 V. Main > Support 命令
名称
Main > Support > FactoryReset — 将设备重置为出厂默认设置。
大纲
FactoryReset
FactoryReset ResetAll
描述
此命令位于 Main_Menu > Support 视图下。 您可以使用此命令将设备重置为出厂默认设置。 如果您将初始密码更改为其他值,运行此命令后,密码将重置为初始默认值。
注意:
在使用此命令重置已从高可用性配置中删除的节点之前,需要执行以下过程:
从已删除的节点断开以太网电缆。
从已删除的节点断开光纤通道电缆。
选项
- FactoryReset
使用此命令将设备重置为出厂默认设置。
- FactoryReset ResetAll
使用此命令可在非交互模式下重置设备出厂安装的映像。
示例
从设备的 shell 菜单开始恢复出厂设置
- 打开一个 SSH 会话,并以管理员身份登录到设备。
- 输入 Main_Menu > Support > FactoryReset。 此命令将显示以下消息,并且在开始恢复出厂设置之前需要您回答以下问题。
Appliance factory reset will reset the entire system to the factory installed image. The appliance will have the following components reset to the factory restored settings/image: 1) Appliance Operating System 2) Appliance Software 3) NetBackup Software 4) Tape media configuration on the master server 5) Networking configuration 6) Storage configuration and backup data (optionally retain) - [Info] Running factory reset validation...please wait (approx 2 mins) - [Info] Factory reset validation successful. RESET NETWORK CONFIGURATION [Optional] -- Resets the IP and routing configuration. -- Resets the DNS configuration. >> Do you want to reset the network configuration? [yes/no] (yes) no RESET STORAGE CONFIGURATION and BACKUP DATA [Optional] -- Removes all the images on the AdvancedDisk and MSDP storage pools. -- Resets the storage partitions. -- Resets storage expansion units, if any. >> Do you want to delete images and reset backup data? [yes/no] (yes) >> Resetting the storage configuration will remove all backup data on the storage partitions and any connected expansion units. This is not reversible. Are you sure you want to reset storage configuration? [yes/no] (yes) >> A reboot of the appliance is required to complete the factory reset. Reboot automatically after reset? [yes/no] (no) yes >> Automatically rebooting after the reset will not provide you with an opportunity to review the progress/final status of the reset. Are you sure you would like to automatically reboot? [yes/no] (no) yes
- 回答这些问题之后,将显示以下摘要信息:
FACTORY RESET SUMMARY --------------------- Reset Appliance OS, software configuration : [YES] Reset Appliance network configuration : [NO] Reset Appliance storage configuration (REMOVE DATA) : [YES] Auto reboot after reset? : [YES] Appliance will make the following version changes: +------------------------------------------------------------------------------+ | Appliance | Current Version | Reverted Version | |------------+--------------------------------+--------------------------------| |v49 |NetBackup 7.6.0.1 Appliance |NetBackup 7.6.0.1 Appliance | | |2.6.0.1 |2.6.0.1 | +------------------------------------------------------------------------------+
- 将显示以下警告。 如果要开始恢复出厂设置操作,请输入 Yes。
WARNING: an Appliance Factory reset cannot be reversed! Continue with factory reset? yes
继续恢复出厂设置时会显示以下摘要消息:
- [Info] PERFORMING APPLIANCE RESET TO FACTORY STATE ON : abc123.example.com - [Info] Delete checkpoints (type: NON_FACT) succeeded - [Info] Reset of the appliance to FACTORY STATE successful. - [Info] Stopping NetBackup processes... (6 mins approx) - [Info] Moving NetBackup Appliance Directory to ce-win21-urmi1... - [Info] Acquired lock on the storage. - [Info] Resetting the storage configuration... - [Info] Checking whether the 'MSDP' storage partition exists... - [Info] Initiating deletion of 'MSDP' storage partition... - [Info] Unmounting the 'MSDP' partition '0'... - [Info] Deleting the 'MSDP' partition '0'... - [Info] Checking whether the 'Catalog' storage partition exists... - [Info] Initiating deletion of 'Catalog' storage partition... - [Info] Unmounting the 'Catalog' partition '0'... - [Info] Deleting the 'Catalog' partition '0'... - [Info] Checking whether the 'Configuration' storage partition exists... - [Info] Initiating deletion of 'Configuration' storage partition... - [Info] Unmounting the 'Configuration' partition '0'... - [Info] Deleting the 'Configuration' partition '0'... - [Info] Checking whether the 'AdvancedDisk' storage partition exists... - [Info] Initiating deletion of 'AdvancedDisk' storage partition... - [Info] Unmounting the 'AdvancedDisk' partition '0'... - [Info] Deleting the 'AdvancedDisk' partition '0'... - [Info] Removing the storage configuration... - [Warning] Failed to query SCSI device '/dev/system/root'. - [Warning] Failed to query SCSI device '/dev/system/root'. >> A reboot of the appliance is required to complete the factory reset. Reboot now?[yes/no] (no)yes Rebooting the appliance now... - [Info] Rebooting abc123.example.com... Broadcast message from root (Mon Nov 25 11:56:39 2013): The system is going down for reboot NOW! - [Info] Rebooting appliance to complete the reset. Please reconnect to the Appliance shell menu to continue using this appliance