Veritas NetBackup™ 5240 Appliance Product Description
- About the NetBackup 5240 Appliance
- NetBackup 5240 Appliance overview
- Features and components of the NetBackup 5240 Appliance
- NetBackup 5240 Appliance front panel disk drive configurations
- NetBackup 5240 Appliance front panel USB port
- NetBackup 5240 Appliance control panel
- NetBackup 5240 Appliance rear panel
- NetBackup 5240 Appliance I/O configuration options
- NetBackup 5240 Appliance total I/O on-board and PCIe ports
- Customizable I/O configurations by slot for existing NetBackup 5240 Appliance installations
- QLE2692 dual-port 16Gb Fibre Channel host bus adapter
- Intel X710-DA2 dual-port 10Gb Ethernet card
- Dual-port 10 Gb Ethernet card with SFP+ transceiver ports
- QLE8442 dual-port 10Gb Ethernet/iSCSI capable card with SFP+ modules
- QLE2562 dual-port 8Gb Fibre Channel host bus adapter with SFP+ modules
- Quad-port 1Gb Ethernet card with RJ45 connectors
- SAS tape-out adapter
- NetBackup 5240 Appliance Network Interface Port locations and speeds
- NetBackup 5240 Appliance I/O configuration options
- About the Veritas 2U12 49TB Storage Shelf
- NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf cables
- Appendix A. Technical specifications and compliance standards
- NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf technical specifications
- Environmental specifications
- Protocol standards
- Regulatory, compliance, and certification information
Environmental specifications
The following table lists the environmental specifications for the NetBackup 5240 Appliance and the Veritas 2U12 49TB Storage Shelf.
Table: NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf environmental specifications
Specification | NetBackup 5240 Appliance / Veritas 2U12 49TB Storage Shelf |
|---|---|
Operating temperature | ASHRAE A2 (10°C to 35°C ) (50°F to 95°F) |
Non-operating temperature | -25°C to 70°C (-13°F to 158°F) The non-operating temperature is defined as the temperature of the system when the system is turned off. It is also referred to as the storage temperature. Veritas recommends that you do not store the system in an environment where the temperatures fall outside of the listed temperature range. |
Operating humidity (Relative Humidity) | 20% RH to 80% RH |
Non-operating humidity | 8% RH to 90% RH |
Operating altitude | -30 to 3000 m with ASHRAE A2 class derating (0 to 10,000 ft) |
Temperature gradient | 10°C/hour (50°F/hour) |
See NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf technical specifications.
See Protocol standards.