Veritas NetBackup™ Appliance SNMP Trap Reference Guide
- Overview
- SNMP hardware traps
- Appendix A. Management Information Base (MIB) file contents
vrtsfanTrap
OID: 1.3.6.1.4.1.48328.3.9.1.3
The vrtsfanTrap monitors the status of the appliance fans. If you receive an alert, it means that one or more of the system fans has experienced an error. Either a fan has stopped working, or the fan rpm has crossed the threshold value that is required for proper system functioning.
Check the SNMP trap or the email alert that you received for additional information to help you determine the exact issue that occurred. You can also check the Monitor > Hardware page of the Web Console of your appliance.
Based on the information from the SNMP trap, the email alert, or the Monitor > Hardware page, take one of the following actions:
Table: Next steps for the vrtsfanTrap
What happened | What to do now |
---|---|
The fan State is Warning, the fan is running slower than the low threshold of 1715 rpm. | Check the system temperature. Check the power supply. If both are normal, contact Veritas Support to replace the fan. |
The fan State is Failed, the fan is missing or has failed. | Contact Veritas Support to replace the fan. |