Veritas 5340 Appliance Product Description
- About the Veritas 5340 Appliance
- Compute node disk drive configurations
- About the compute node control panel
- About the compute node rear panel
- About the Veritas 5U84 Storage Shelves
- About Veritas 5340 Appliance storage shelves
- About the 5U84 Primary Storage Shelf and 5U84 Expansion Storage Shelf rear components
- Veritas 5340 Appliance and 5U84 Storage Shelf cables
- Appendix A. Technical specifications, Environmental/Protocol standards, and Compliance standards
- Regulatory, compliance, and certification information
Expansion I/O module SAS Activity LED location and conditions
This section discusses the location of the SAS Activity LEDs on the Expansion I/O modules and the SAS Activity LED conditions.
Table: Expansion I/O module SAS Activity LED conditions
Condition | Activity LED (green) | Fault LED (amber) |
---|---|---|
No Cable Present | Off | Off |
Cable Present All links up, no activity. | On | Off |
Cable Present All links up. | Flash with aggregate port activity | Off |
Critical Fault
| Off | On |
Non-Critical Fault Any fault which does not cause the connection to cease operation. For example, not all links established; OVERTEMPERATURE condition detected. | Flash with aggregate port activity | Flashing - One second on; one second off |