Cluster Server 7.3.1 Configuration and Upgrade Guide - Solaris
- Section I. Configuring Cluster Server using the script-based installer
- I/O fencing requirements
- Preparing to configure VCS clusters for data integrity
- About planning to configure I/O fencing
- Setting up the CP server
- Configuring VCS
- Configuring a secure cluster node by node
- Verifying and updating licenses on the system
- Configuring VCS clusters for data integrity
- Setting up disk-based I/O fencing using installer
- Setting up server-based I/O fencing using installer
- Section II. Automated configuration using response files
- Performing an automated VCS configuration
- Performing an automated I/O fencing configuration using response files
- Section III. Manual configuration
- Manually configuring VCS
- Configuring LLT manually
- Configuring VCS manually
- Configuring VCS in single node mode
- Modifying the VCS configuration
- Manually configuring the clusters for data integrity
- Setting up disk-based I/O fencing manually
- Setting up server-based I/O fencing manually
- Configuring server-based fencing on the VCS cluster manually
- Setting up non-SCSI-3 fencing in virtual environments manually
- Setting up majority-based I/O fencing manually
- Manually configuring VCS
- Section IV. Upgrading VCS
- Planning to upgrade VCS
- Performing a VCS upgrade using the installer
- Tasks to perform after upgrading to 2048 bit key and SHA256 signature certificates
- Performing an online upgrade
- Performing a rolling upgrade of VCS
- Performing a phased upgrade of VCS
- About phased upgrade
- Performing a phased upgrade using the product installer
- Performing an automated VCS upgrade using response files
- Upgrading VCS using Live Upgrade and Boot Environment upgrade
- Planning to upgrade VCS
- Section V. Adding and removing cluster nodes
- Adding a node to a single-node cluster
- Adding a node to a single-node cluster
- Adding a node to a multi-node VCS cluster
- Manually adding a node to a cluster
- Setting up the node to run in secure mode
- Configuring I/O fencing on the new node
- Adding a node using response files
- Removing a node from a VCS cluster
- Removing a node from a VCS cluster
- Removing a node from a VCS cluster
- Adding a node to a single-node cluster
- Section VI. Installation reference
- Appendix A. Services and ports
- Appendix B. Configuration files
- Appendix C. Configuring LLT over UDP
- Using the UDP layer for LLT
- Manually configuring LLT over UDP using IPv4
- Manually configuring LLT over UDP using IPv6
- Appendix D. Configuring the secure shell or the remote shell for communications
- Appendix E. Installation script options
- Appendix F. Troubleshooting VCS configuration
- Appendix G. Sample VCS cluster setup diagrams for CP server-based I/O fencing
- Appendix H. Reconciling major/minor numbers for NFS shared disks
- Appendix I. Upgrading the Steward process
Configuring SNMP trap notification
You can choose to configure VCS to send event notifications to SNMP management consoles. You need to provide the SNMP management console name to be notified and message severity levels.
Note that you can also configure the notification after installation.
Refer to the Cluster Server Administrator’s Guide for more information.
To configure the SNMP trap notification
- Review the required information to configure the SNMP notification feature of VCS.
- Specify whether you want to configure the SNMP notification.
If you skip this option and if you had installed a valid HA/DR license, the installer presents you with an option to configure this cluster as global cluster. If you did not install an HA/DR license, the installer proceeds to configure VCS based on the configuration details you provided.
- Provide information to configure SNMP trap notification.
Provide the following information:
Enter the SNMP trap daemon port.
Enter the SNMP trap daemon port: [b,q,?] (162)
Enter the SNMP console system name.
Enter the SNMP console system name: [b,q,?] sys5
Enter the minimum security level of messages to be sent to each console.
Enter the minimum severity of events for which SNMP traps should be sent to sys5 [I=Information, W=Warning, E=Error, S=SevereError]: [b,q,?] E
Add more SNMP consoles, if necessary.
If you want to add another SNMP console, enter y and provide the required information at the prompt.
Would you like to add another SNMP console? [y,n,q,b] (n) y Enter the SNMP console system name: [b,q,?] sys4 Enter the minimum severity of events for which SNMP traps should be sent to sys4 [I=Information, W=Warning, E=Error, S=SevereError]: [b,q,?] S
If you do not want to add, answer n.
Would you like to add another SNMP console? [y,n,q,b] (n)
- Verify and confirm the SNMP notification information.
SNMP Port: 162 Console: sys5 receives SNMP traps for Error or higher events Console: sys4 receives SNMP traps for SevereError or higher events Is this information correct? [y,n,q] (y)
More Information