Restarting servers
Some configuration changes do not take effect until the associated server is restarted. Therefore, some configuration problems can be solved by stopping and restarting the associated server. For example, when you change AD Domain settings, you need to restart the CIFS server.
Table: Commands to start and stop servers shows commands you can use to start and stop Access Appliance servers.
Table: Commands to start and stop servers
Command | Definition |
---|---|
Backup> start | Starts all configured backup services. |
Backup> stop | Stops all configured backup services. |
CIFS> server start | Starts the CIFS server. |
CIFS> server stop | Stops the CIFS server. |
NFS> server start | Starts the NFS server. |
NFS> server stop | Stops the NFS server. |
Storage> iscsi start | Starts the iSCSI initiator service. |
Storage> iscsi stop | Stops the iSCSI initiator service. |
Note: