検索クエリーを入力してください
<book_title> を検索 ...
Veritas NetBackup™ Appliance Commands Reference Guide
Last Published:
2017-11-17
Product(s):
Appliances (3.1 (5340), 3.1 (5330), 3.1 (5240), 3.1 (5230), 3.1 (5220))
- Overview
- 付録 A. Main > Appliance commands
- 付録 B. Main > Manage > FibreChannel commands
- 付録 C. Main > Manage > HighAvailability commands
- 付録 D. Main > Manage > Libraries commands
- 付録 E. Main > Manage > Libraries > Advanced > ACS commands
- 付録 F. Main > Manage > License commands
- 付録 G. Main > Manage > MountPoints commands
- 付録 H. Main > Manage > NetBackup CLI commands
- 付録 I. Main > Manage > OpenStorage commands
- 付録 J. Main > Manage > Software commands
- 付録 K. Main > Manage > Storage commands
- 付録 L. Main > Manage > Tapes commands
- 付録 M. Main > Manage > Certificates commands
- 付録 N. Main > Monitor commands
- 付録 O. Main > Network commands
- 付録 P. Main > Network > Security (IPsec) commands
- 付録 Q. Main > Reports commands
- 付録 R. Main > Settings commands
- 付録 S. Main > Settings > Alerts commands
- 付録 T. Main > Settings > Notifications view commands
- 付録 U. Main > Settings > Security commands
- 付録 V. Main > Support commands
名前
Main > Support > Show — ハードウェア診断のための参照テーブルを表示します。
概要
Show HW-DiagnosisHelp
説明
このコマンドはハードウェア診断のための参照テーブルを表示するのに使います。参照テーブルを使って、ハードウェアのさまざまなエラー状態 (重要な警告または致命的エラーなど) の潜在的な原因を識別できます。
オプション
- Show HW-DiagnosisHelp
このコマンドはハードウェア診断のための参照テーブルを表示するために使います。
例
次は、Main > Support > Show HW-DiagnosisHelp コマンドを実行すると表示される情報の例です。
Reference Chart +-----------------------------------------------------------------------------+ |ID| Device | State | Diagnosis | |--+-----------+-------+------------------------------------------------------| | | | | Check if both the Power Supply Units are cabled | | |Power | | and is receiving power | |1 |Supply |Warning| | | | | | * If PS is cabled and receiving power, call | | | | | Veritas support to replace the Power Supply Unit | |--+-----------+-------+------------------------------------------------------| | | | | Check the status column. | | | | | | | | | | * If the status is "Disabled", run the test again.| |2 |CPU |Failed | (ipmitool may sometimes report incorrect CPU | | | | | status) | | | | | | | | | | * If the failure persists, call Veritas support to| | | | | replace the CPU | |--+-----------+-------+------------------------------------------------------| | | | | Check the status column | | | | | | | | | | * "Device Absent" indicates that the fan is either| | | | | not inserted correctly or the power supply cable | |3 |Fan |Failed | for the fan is loose. | | | | | | | | | | * If the fan is inserted correctly or the power | | | | | supply cable is inserted correctly on the | | | | | motherboard, call Veritas support to replace the | | | | | fan. | |--+-----------+-------+------------------------------------------------------| | | | | Check the Speed column. | | | | | | | | | | * Speed will be above the high water mark levels. | | | | | Check if any other fan is in failed state. If yes,| | | | | call Veritas support to replace the failed fan. | |4 |Fan |Warning| Once replaced, the speed will stay within water | | | | | mark level. | | | | | | | | | | * If none of the other fans have failed, check the| | | | | temperature table. If the temperature of appliance| | | | | rises, then fan speed increases unless proper | | | | | cooling is provided to the machine. | |--+-----------+-------+------------------------------------------------------| | | | | Check the "Slot number" column | |5 |Disk |Failed | | | | | | * Call Veritas support to replace the drive in | | | | | that slot | |--+-----------+-------+------------------------------------------------------| | | | | Check the "Status" column | | | | | | | | | | * Drive in that slot was supposed to be in | | | | | "Hotspare" state. It might have changed the state | |6 |Disk |Warning| due to a drive failure in another slot. | | | | | | | | | | * If none of the other drives are in failed state,| | | | | copyback needs to be initiated so that the drive | | | | | in this particular slot becomes a "hotspare" | |--+-----------+-------+------------------------------------------------------| |7 |Fiber |Failed | * Call Veritas support to replace the FC card | | |Channel | | | |--+-----------+-------+------------------------------------------------------| | | | | * Make sure enough cooling is provided so that the| |8 |Temperature|Warning| temperature does not cross the high threshold | | | | | limit | |--+-----------+-------+------------------------------------------------------| | | | | Check the "status" column | |9 |RAID |Failed | | | | | | * Multiple drive failure can result in RAID volume| | | | | going offline | |--+-----------+-------+------------------------------------------------------| | | | | Check the "Write Policy" column | | | | | | | | | | * If it is in "WriteThrough" mode, check the "RAID| | | | | adapter" table. If either the "BBU learn cycle | | | | | active" field for that RAID adapter is "yes" OR if| | | | | the "BBU charge" field is less than 60%, the write| | | | | policy will temporarily remain in WriteThrough | | | | | mode. | | | | | | |10|RAID |Warning| * If "BBU learn cycle active" is not "yes" AND | | | | | "BBU charge" is more than 60%, change the write | | | | | policy for RAID-6 to "WriteBack with BBU" using | | | | | MegaCli | | | | | | | | | | * Status can be "Degraded" or "Partially | | | | | degraded". One or more drives might have failed. | | | | | Call Veritas support to replace the failed drive | | | | | (s) and wait for the rebuild and copyback | | | | | operation to complete. | |--+-----------+-------+------------------------------------------------------| | | | | Check "Adapter status" and "BBU status" column | | | | | | | | | | * Either adapter NVRAM, Memory, or Flash of the | | | | | adapter is absent or bad. Call Veritas support to | |11|Adapter |Failed | replace the RAID card | | | | | | | | | | * Either BBU,BBU voltage or BBU temperature is not| | | | | OK, call Veritas support to replace the BBU on | | | | | that adapter. | |--+-----------+-------+------------------------------------------------------| | | | | * This is a temporary state when either the BBU | |12|Adapter |Warning| learn cycle is active or the BBU charge is less | | | | | than 60% | |--+-----------+-------+------------------------------------------------------| | | | | * Warning indicates that either the PCI card in | |13|PCI |Warning| not inserted in the compatible slot or an | | | | | unsupported card is inserted. | +-----------------------------------------------------------------------------+