NetBackup status code: 290
Explanation: This error occurs when more than one error is encountered during an eject procedure by vltopmenu. Any "eject" errors that range from 291 to 300 may have occurred in any of the sessions being ejected.
Recommended Action: For detailed information, review the Vault debug log in the following directory:
UNIX and Linux: /usr/openv/netbackup/logs/vault
Windows: install_path\NetBackup\logs\vault
Also review the summary.log
in each of the sidxxx
directories that had problems:
UNIX and Linux: /usr/openv/netbackup/vault/sessions/vault_name/sidxxx
Windows: install_path\NetBackup\vault\sessions\vault_name\sidxxx
(where xxx is the session ID)
After the problem is identified and corrected, the media that were not ejected may need to be ejected manually by means of vlteject or vltopmenu.
This error often indicates that the media were left in the off-site Vault volume group but physically reside in the robot or the robotic MAP.
To solve this problem, do one of the following:
Manually remove any media that are in the off-site Vault volume group but are still in the robotic library.
Inventory the robotic library. An inventory puts any media that were in the off-site Vault volume group back into the robotic volume group. Then rerun the Vault sessions that failed.
Click here to view technical notes and other information in the Veritas Knowledge Base about this status code.