Veritas NetBackup™ Logging Reference Guide
- Using logs
- About unified logging
- About legacy logging
- About global logging levels
- Troubleshooting error messages in the NetBackup Administration Console
- Backup process and logging
- Media and device processes and logging
- Restore process and logging
- Advanced Backup and Restore Features
- Storage logging
- NetBackup Deduplication logging
- OpenStorage Technology (OST) logging
- Storage lifecycle policy (SLP) and Auto Image Replication (A.I.R.) logging
- Snapshot technologies
- Locating logs
- Java-based administration console logging
About query strings used with the vxlogview command
Use the vxlogview command to display the logs that unified logging generates. The vxlogview command includes the following option: -w (- -where) QueryString.
QueryString represents a text expression similar to a database WHERE clause. The query string expression is used to retrieve log entries from the unified logging system. The expression is a combination of relational operators, constant integers, constant strings, and names of log fields that evaluate to a single value. Expressions are grouped by logical operators such as AND and OR.
The supported relational operators are as follows:
< | less than |
> | greater than |
<= | less than and equal to |
>= | greater than and equal to |
= | equal to |
!= | not equal to |
The supported logical operators are as follows:
&& | logical AND |
|| | logical OR |
Table: Data types for fields shows data types for specific fields as well as description and an example. When more than one example is listed, both examples produce the same results.
Table: Data types for fields
Field name | Type | Description | Example |
---|---|---|---|
PRODID | Integer or string | Provide the product ID or the abbreviated name of product. | PRODID = 51216 PRODID = 'NBU' |
ORGID | Integer or string | Provide the originator ID or the abbreviated name of the component. | ORGID = 116 ORGID = 'nbpem' |
PID | Long Integer | Provide the process ID | PID = 1234567 |
TID | Long Integer | Provide the thread ID | TID = 2874950 |
STDATE | Long Integer or string | Provide the start date in seconds or in the locale-specific short date and time format. For example, a locale can have the format 'mm/dd/yy hh:mm:ss AM/PM' | STDATE = 98736352 STDATE = '4/26/11 11:01:00 AM' |
ENDATE | Long Integer or string | Provide the end date in seconds or in the locale-specific short date and time format. For example, a locale can have the format 'mm/dd/yy hh:mm:ss AM/PM' | ENDATE = 99736352 ENDATE = '04/27/11 10:01:00 AM' |
PREVTIME | String | Provide the hours in 'hh:mm:ss' format. This field should be used only with operators =, <, >, >=, and <= | PREVTIME = '2:34:00' |
SEV | Integer | Provide one of the following possible severity types: 0 = INFO 1 = WARNING 2 = ERR 3 = CRIT 4 = EMERG | SEV = 0 SEV = INFO |
MSGTYPE | Integer | Provide one of the following possible message types: 0 = DEBUG (debug messages) 1 = DIAG (diagnostic messages) 2 = APP (application messages) 3 = CTX (context messages) 4 = AUDIT (audit messages) | MSGTYPE = 1 MSGTYPE = DIAG |
CTX | Integer or string | Provide the context token as string identifier or 'ALL' to get all the context instances to be displayed. This field should be used only with the operators = and !=. | CTX = 78 CTX = 'ALL' |
Consider the following when writing a query string.
Case sensitivity | Field names, severity types, and message types are not case-sensitive. For example, the following are valid entries:
|
String constants | String constants should be given in single quotes. For example, PRODID = 'NBU' |
Dates | Start and end dates can be provided in the following formats:
|
Table: Examples of query strings provides examples of query strings.
Table: Examples of query strings
Example | Description |
---|---|
(PRODID == 51216) && ((PID == 178964) || ((STDATE == '2/5/15 09:00:00 AM') && (ENDATE == '2/5/15 12:00:00 PM')) | Retrieves the log file message for the NetBackup product ID 51216 between 9AM and 12PM on 2015-05-02. |
((prodid = 'NBU') && ((stdate >= '11/18/14 00:00:00 AM') && (endate <= '12/13/14 12:00:00 PM'))) || ((prodid = 'BENT') && ((stdate >= '12/12/14 00:00:00 AM') && (endate <= '12/25/14 12:00:00 PM'))) | Retrieves the log messages for the NetBackup product NBU between 2014-18-11 and 2014-13-12 and the log messages for the NetBackup product BENT between 2014-12-12 and 2014-25-12. |
(STDATE <= '04/05/15 0:0:0 AM') | Retrieves the log messages that were logged on or before 2015-05-04 for all of the installed Veritas products. |